# IPMI Controller
|
|
|
|
Advanced web-based fan control for Dell servers with IPMI support. Automatically adjust fan speeds based on temperature readings from IPMI sensors and optional HTTP lm-sensors endpoint.
|
|
|
|
**Version:** 1.0.0
|
|
**Author:** ImpulsiveFPS
|
|
**License:** MIT
|
|
|
|
---
|
|
|
|
## Features
|
|
|
|
- 🌡️ **Temperature Monitoring** - Real-time CPU, inlet, exhaust, and PCIe temperature monitoring
|
|
- 🌀 **Automatic Fan Control** - Dynamic fan speed adjustment based on customizable temperature curves
|
|
- 📊 **Fan Groups** - Group fans together for unified control
|
|
- 📈 **Custom Curves** - Create custom fan curves and assign them to specific fan groups
|
|
- 🖥️ **HTTP Sensors** - Optional integration with lm-sensors for additional temperature data
|
|
- 🎨 **Dark/Light Theme** - Choose your preferred visual style
|
|
- 🔒 **Secure** - Built-in authentication and session management
|
|
- 🚀 **Auto-Start** - Automatically resumes operation after system restart
|
|
|
|
---
|
|
|
|
## Table of Contents
|
|
|
|
- [Prerequisites](#prerequisites)
|
|
- [Installation](#installation)
|
|
- [IPMI Setup](#ipmi-setup)
|
|
- [HTTP Sensors Setup (Optional)](#http-sensors-setup-optional)
|
|
- [First Run](#first-run)
|
|
- [Configuration](#configuration)
|
|
- [Troubleshooting](#troubleshooting)
|
|
- [Support](#support)
|
|
|
|
---
|
|
|
|
## Prerequisites
|
|
|
|
### Hardware Requirements
|
|
|
|
- Dell server with IPMI support (iDRAC)
|
|
- Network connectivity to the server's IPMI interface
|
|
- A machine to run the IPMI Controller (can be the same server or a separate management host)
|
|
|
|
### Software Requirements
|
|
|
|
- Python 3.8+
|
|
- `ipmitool` (for IPMI communication)
|
|
- Linux-based system (tested on Ubuntu/Debian)
|
|
|
|
### Installing ipmitool
|
|
|
|
```bash
|
|
# Ubuntu/Debian
|
|
sudo apt update
|
|
sudo apt install ipmitool
|
|
|
|
# Verify installation
|
|
ipmitool -V
|
|
```
|
|
|
|
---
|
|
|
|
## Installation
|
|
|
|
### 1. Clone the Repository
|
|
|
|
```bash
|
|
git clone https://github.com/ImpulsiveFPS/IPMI-Controller.git
|
|
cd IPMI-Controller
|
|
```
|
|
|
|
### 2. Install Python Dependencies
|
|
|
|
```bash
|
|
pip install -r requirements.txt
|
|
```
|
|
|
|
Required packages:
|
|
- fastapi
|
|
- uvicorn
|
|
- pydantic
|
|
- requests
|
|
|
|
### 3. Start the Application
|
|
|
|
```bash
|
|
python3 web_server.py
|
|
```
|
|
|
|
The web interface will be available at `http://localhost:8000`
|
|
|
|
### 4. (Optional) Systemd Service
|
|
|
|
To run the controller as a system service:
|
|
|
|
```bash
|
|
sudo cp ipmi-controller.service /etc/systemd/system/
|
|
sudo systemctl daemon-reload
|
|
sudo systemctl enable ipmi-controller
|
|
sudo systemctl start ipmi-controller
|
|
```
|
|
|
|
---
|
|
|
|
## IPMI Setup
|
|
|
|
### Step 1: Configure iDRAC/IPMI Network Settings
|
|
|
|
1. Boot into your Dell server's BIOS/F2 setup
|
|
2. Navigate to **iDRAC Settings** → **Network**
|
|
3. Configure a static IP address for iDRAC (e.g., `192.168.5.191`)
|
|
4. Save and exit
|
|
|
|
Alternatively, configure via iDRAC web interface:
|
|
1. Access iDRAC at its current IP
|
|
2. Go to **iDRAC Settings** → **Network** → **IPV4 Settings**
|
|
3. Set static IP, subnet mask, and gateway
|
|
4. Apply changes
|
|
|
|
### Step 2: Create IPMI User
|
|
|
|
#### Method 1: Via iDRAC Web Interface (Recommended)
|
|
|
|
1. Log into iDRAC web interface
|
|
2. Go to **iDRAC Settings** → **User Authentication** → **Local Users**
|
|
3. Click **Add User** or edit an existing user
|
|
4. Configure:
|
|
- **User Name:** `root` (or your preferred username)
|
|
- **Password:** Strong password
|
|
- **IPMI LAN Privilege:** Administrator
|
|
- **Enable IPMI over LAN:** ✓ Checked
|
|
5. Save changes
|
|
|
|
#### Method 2: Via ipmitool (Local Access Required)
|
|
|
|
```bash
|
|
# List current users
|
|
sudo ipmitool user list 1
|
|
|
|
# Create new user (ID 3)
|
|
sudo ipmitool user set name 3 root
|
|
sudo ipmitool user set password 3 YOUR_PASSWORD
|
|
sudo ipmitool channel setaccess 1 3 callin=on ipmi=on link=on privilege=4
|
|
sudo ipmitool user enable 3
|
|
|
|
# Verify
|
|
sudo ipmitool user list 1
|
|
```
|
|
|
|
### Step 3: Enable IPMI over LAN
|
|
|
|
```bash
|
|
# Enable IPMI over LAN
|
|
sudo ipmitool lan set 1 ipsrc static
|
|
sudo ipmitool lan set 1 ipaddr 192.168.5.191
|
|
sudo ipmitool lan set 1 netmask 255.255.255.0
|
|
sudo ipmitool lan set 1 defgw ipaddr 192.168.5.1
|
|
sudo ipmitool lan set 1 access on
|
|
|
|
# Verify settings
|
|
sudo ipmitool lan print 1
|
|
```
|
|
|
|
### Step 4: Test IPMI Connection
|
|
|
|
From another machine on the network:
|
|
|
|
```bash
|
|
ipmitool -I lanplus -H 192.168.5.191 -U root -P YOUR_PASSWORD chassis status
|
|
```
|
|
|
|
If successful, you'll see server power status and other information.
|
|
|
|
---
|
|
|
|
## HTTP Sensors Setup (Optional)
|
|
|
|
HTTP sensors allow you to integrate additional temperature readings from lm-sensors running on your Proxmox host or other systems. This provides more granular CPU core temperatures.
|
|
|
|
### Step 1: Install lm-sensors on Remote Host
|
|
|
|
```bash
|
|
# On Proxmox or target host
|
|
sudo apt update
|
|
sudo apt install lm-sensors
|
|
|
|
# Detect sensors
|
|
sudo sensors-detect
|
|
|
|
# Test
|
|
sensors
|
|
```
|
|
|
|
### Step 2: Create HTTP Sensor Server Script
|
|
|
|
Create `sensor-server.py` on the remote host:
|
|
|
|
```python
|
|
#!/usr/bin/env python3
|
|
"""Simple HTTP server for lm-sensors data"""
|
|
|
|
from http.server import HTTPServer, BaseHTTPRequestHandler
|
|
import json
|
|
import subprocess
|
|
|
|
class SensorHandler(BaseHTTPRequestHandler):
|
|
def do_GET(self):
|
|
if self.path == '/sensors':
|
|
try:
|
|
result = subprocess.run(['sensors', '-j'],
|
|
capture_output=True, text=True)
|
|
data = json.loads(result.stdout)
|
|
|
|
self.send_response(200)
|
|
self.send_header('Content-Type', 'application/json')
|
|
self.send_header('Access-Control-Allow-Origin', '*')
|
|
self.end_headers()
|
|
self.wfile.write(json.dumps(data).encode())
|
|
except Exception as e:
|
|
self.send_response(500)
|
|
self.end_headers()
|
|
self.wfile.write(json.dumps({'error': str(e)}).encode())
|
|
else:
|
|
self.send_response(404)
|
|
self.end_headers()
|
|
|
|
def log_message(self, format, *args):
|
|
pass # Suppress logs
|
|
|
|
if __name__ == '__main__':
|
|
server = HTTPServer(('0.0.0.0', 8888), SensorHandler)
|
|
print("Sensor server running on port 8888")
|
|
server.serve_forever()
|
|
```
|
|
|
|
### Step 3: Run Sensor Server
|
|
|
|
```bash
|
|
python3 sensor-server.py
|
|
```
|
|
|
|
Or create a systemd service:
|
|
|
|
```ini
|
|
# /etc/systemd/system/sensor-server.service
|
|
[Unit]
|
|
Description=LM Sensors HTTP Server
|
|
After=network.target
|
|
|
|
[Service]
|
|
Type=simple
|
|
ExecStart=/usr/bin/python3 /path/to/sensor-server.py
|
|
Restart=always
|
|
User=root
|
|
|
|
[Install]
|
|
WantedBy=multi-user.target
|
|
```
|
|
|
|
```bash
|
|
sudo systemctl enable sensor-server
|
|
sudo systemctl start sensor-server
|
|
```
|
|
|
|
### Step 4: Test HTTP Endpoint
|
|
|
|
```bash
|
|
curl http://192.168.5.200:8888/sensors
|
|
```
|
|
|
|
You should see JSON output with sensor readings.
|
|
|
|
### Step 5: Configure in IPMI Controller
|
|
|
|
1. During setup wizard (Step 3), check "Enable HTTP Sensor"
|
|
2. Enter URL: `http://192.168.5.200:8888/sensors`
|
|
3. Click "Test HTTP Sensor" to verify connection
|
|
4. Complete setup
|
|
|
|
---
|
|
|
|
## First Run
|
|
|
|
### Initial Setup Wizard
|
|
|
|
1. **Step 1: Create Admin Account**
|
|
- Username: Choose your admin username
|
|
- Password: Minimum 6 characters
|
|
- Confirm password
|
|
|
|
2. **Step 2: IPMI Configuration**
|
|
- Host/IP: Your iDRAC IP (e.g., `192.168.5.191`)
|
|
- Port: Usually `623`
|
|
- Username: IPMI username (e.g., `root`)
|
|
- Password: IPMI password
|
|
- Click "Test Connection" to verify
|
|
|
|
3. **Step 3: HTTP Sensor (Optional)**
|
|
- Enable HTTP Sensor: Check if using lm-sensors
|
|
- URL: `http://your-server:8888/sensors`
|
|
- Click "Test HTTP Sensor" to verify
|
|
|
|
4. **Enable Auto Fan Control**
|
|
- Check "Enable Auto Fan Control" to start automatic control immediately
|
|
- This activates the default "Balanced" fan curve
|
|
|
|
5. **Complete Setup**
|
|
- Click "Complete Setup" to finish
|
|
- You'll be logged in automatically
|
|
|
|
---
|
|
|
|
## Configuration
|
|
|
|
### Fan Curves
|
|
|
|
Fan curves define how fan speed responds to temperature:
|
|
|
|
1. Go to **Curves** tab
|
|
2. Click **+ Add Curve**
|
|
3. Configure:
|
|
- **Curve Name:** e.g., "Silent", "Performance"
|
|
- **Group:** (Optional) Assign to specific fan group
|
|
- **Points:** Add temperature → speed mappings
|
|
- Example: `30°C → 20%`, `50°C → 50%`, `70°C → 100%`
|
|
4. Click **Save Curve**
|
|
5. Click **Activate** to apply the curve
|
|
|
|
### Fan Groups
|
|
|
|
Groups allow unified control of multiple fans:
|
|
|
|
1. Go to **Fan Groups** tab
|
|
2. Click **+ Create First Group**
|
|
3. Enter group name
|
|
4. Select fans to include
|
|
5. Click **Save Group**
|
|
6. Use **Set Speed** to control all fans in group
|
|
|
|
### Quick Controls
|
|
|
|
- **Start Auto:** Enable automatic fan control
|
|
- **Stop Auto:** Return to manual/BIOS control
|
|
- **Manual Speed Slider:** Set all fans to specific speed
|
|
- **Identify Fan:** Flash individual fan to 100% for identification
|
|
|
|
---
|
|
|
|
## Troubleshooting
|
|
|
|
### Connection Issues
|
|
|
|
**"Not connected" status:**
|
|
- Verify IPMI IP address is correct
|
|
- Check network connectivity: `ping 192.168.5.191`
|
|
- Test with ipmitool: `ipmitool -I lanplus -H 192.168.5.191 -U root chassis status`
|
|
- Ensure IPMI user has Administrator privileges
|
|
- Verify IPMI over LAN is enabled
|
|
|
|
**"Connection timeout":**
|
|
- Check firewall rules on IPMI network
|
|
- Verify port 623 is open
|
|
- Try increasing timeout in settings
|
|
|
|
### Fan Control Not Working
|
|
|
|
**Fans not responding to speed changes:**
|
|
- Some Dell servers require manual fan control to be enabled first
|
|
- Check IPMI logs for errors
|
|
- Verify fan IDs are correct
|
|
- Try using individual fan controls to test
|
|
|
|
**"Manual fan control not supported":**
|
|
- Some server models don't support external fan control
|
|
- Check Dell documentation for your specific model
|
|
- Try updating iDRAC firmware
|
|
|
|
### HTTP Sensor Issues
|
|
|
|
**"HTTP Sensor not working":**
|
|
- Verify sensor server is running: `curl http://ip:8888/sensors`
|
|
- Check firewall on sensor host
|
|
- Ensure lm-sensors is properly configured
|
|
- Verify URL format includes `http://` prefix
|
|
|
|
---
|
|
|
|
## Support
|
|
|
|
- 🐛 **Report Bugs:** https://github.com/ImpulsiveFPS/IPMI-Controller/issues
|
|
- 📁 **GitHub Repo:** https://github.com/ImpulsiveFPS/IPMI-Controller
|
|
- ☕ **Support on Ko-fi:** https://ko-fi.com/impulsivefps
|
|
|
|
---
|
|
|
|
## Acknowledgments
|
|
|
|
Built with:
|
|
- [FastAPI](https://fastapi.tiangolo.com/) - Web framework
|
|
- [Heroicons](https://heroicons.com/) - Icons
|
|
- [Lucide](https://lucide.dev/) - Additional icons
|
|
|
|
---
|
|
|
|
**IPMI Controller v1.0.0 - Built by ImpulsiveFPS** |